pco.edge 26 sCMOS Camera

Highest 26 MPix resolution cooled SCMOS camera with true global shutter

 

Description

The new pco.edge 26 sCMOS camera is designed to maximise the amount of information per image, making it perfect for microscopy, quality control, high throughput screening and other mesoscopic applications. The pco.edge 26 offers you 5120 x 5120 pixel resolution with 2.5 x 2.5 µm² pixel size, thereby achieving the maximum level of spatial resolution. This even applies for microscopic imaging with low magnification. The true charge domain global shutter allows exceptionally low readout noise and dark current. Combined with its adjustable cooling, the pco.edge 26 enables you also to extend your exposure times to up to 60 seconds. Use the pco.edge 26 sCMOS camera system with the latest software from PCO.

Key Features:

  • true charge domain global shutter
  • ultra high resolution: 5120 x 5120 pixel
  • exposure time: 5 µs … 60 s
  • pixel size (h x v): 2.5 µm x 2.5 µm
  • dynamic range 66 dB
  • compact design
  • frame rate 7 fps @ 26 MPix
  • adjustable: from – 20 °C to + 20 °C peltier with forced air (fan) and water cooling
  • up to 72 % quantum efficiency
  • USB 3.1 Gen1 data interface

Quantum Efficiency Curve:

View/ Download the datasheet here.

Applications Areas:

  • PALM
  • STORM
  • SPIM
  • spinning disk confocal microscopy
  • FRET
  • FRAP
  • adaptive optic
  • brightfield microscopy
  • fluorescence microscopy
  • digitalpathology
  • light sheet fluorescence microscopy (LSFM)
  • structured illumination microscopy (SIM)
  • high-speed bright field ratio imaging
  • high throughput screening
  • high content screening
  • biochip reading
  • spinning disk confocal microscopy
  • 3D metrology
  • industrial quality inspection

 

Application Examples:

Modular Wafer Inspection with pco.edge 5.5

Silicon carbide (SiC) is a wide bandgap semiconductor, which is especially used for high-power, high-temperature and high-frequency devices due to its high energy efficiency. Despite great improvements in the material quality of SiC substrates and epitaxial wafers within the last years, critical defects like stacking faults (SFs) and basal plane dislocations (BPDs) can still lead to bipolar degradation and finally to complete failure of the device. Read more about this here.

 

Fluorensce Microscopy DNA Micro Arrays with pco.edge series

Microarrays are versatile tools for high throughput screening. Nevertheless they are severely limited. Either the molecules are synthesized in-situ directly on the surface or in-vitro or in-vivo produced externally and then transferred onto the surface. In-situ synthesis shows low yield in terms of purity and restricts therefore the biomolecule probe length to ~50 bp for light-synthesized DNA (Affymetrics) or ~200 bp print-synthesis (Agilent), but allows up to millions of spots per array. Ex-array synthesis on the other hand provides high-purity molecules, but the (bio)synthesis and purification of these molecules is tedious, time consuming and expansive. Also the printing process takes time. Even if one spot can be made per second 100,000 spots will take more than a day. Therefore the idea arose why to copy microarrays. Why not make DNA, RNA and protein microarrays as high quality copies of a high quality original? It worked fine for text books and images. So why not apply it for DNA? Why not build a biomolecule copying machine? A biomolecule xeroxer? Read more about this here.

 

Time Lapse 3D measurements with pco.edge series

Light sheet fluorescence microscopy has previously been demonstrated on a commercially available inverted fluorescence microscope frame using the method of oblique plane microscopy (OPM). In this paper, OPM is adapted to allow time-lapse 3-D imaging of 3-D biological cultures in commercially available glass-bottomed 96-well plates using a stage-scanning OPM approach (ssOPM). Read more about this here.

 

High Speed Florescence Microscopy with pco.edge series / pco.1600 / pco.sensicam

The application shows that the mode and dynamics of trypanosome locomotion are a trait of life within a crowded environment. Using high-speed fluorescence microscopy and ordered micro-pillar arrays we show that the parasites mode of motility is adapted to the density of cells in blood. Read more about this here.

 

3D Flow Field Measurements with pco.edge 5.5/pco.dimax series

Large-volume volumetric flow experiments and their results: The first of these, investigating a thermal plume at low velocities (up to 0.35 m/s) demonstrates the abilities and requirements to reach volume sizes up to and probably beyond one cubic mete Read more about this here.

 

sCMOS Ebook:

View/download the PCO ebook “Everything you always wanted to know about sCMOS cameras”.

PCO Camware Tutorial Series:

 